idw – Informationsdienst Wissenschaft

Nachrichten, Termine, Experten

Grafik: idw-Logo
Science Video Project
idw-Abo

idw-News App:

AppStore

Google Play Store



Instanz:
Teilen: 
16.10.2008 10:32

Optimized Radiation for Prostate Cancer Therapy

Mag. Werner Sommer PR und Kommunikation
Technische Universität Wien

    The determination of the precise anatomical location of a tumor is the prerequisite for setting optimal parameters for radiation treatment of prostate cancer. This approach guarantees that the ionizing radiation only destroys tumorous cells and does not affect other organs in the vicinity of the prostate. In a cooperative study with Innsbruck Medical University and the East-Vienna Center of Social Medicine, two physicists of Vienna University of Technology (TU), evaluated the mean deviation of radiation parameters for prostate cancers and compared various sources of radiation.

    Vienna (TU). - Movement inaccuracies of up to two centimeters may occur in prostate radiation. "During the radiation treatment, patients have to lie on a table for some 20 minutes without moving. Over time, the muscles relax and the pelvis drops. As a consequence, the radiation may focus on the bladder or other organs. In our calculations, we concentrated on the precision of localizing the prostate and on improvement potentials in treatment," explained Karin Poljanc, Assistant Professor at the Atomic Institute of Austrian Universities.

    In a study conducted in cooperation with SMZ Ost (East-Vienna Center of Social Medicine, Danube Hospital), Poljanc and her research associates, Tanja Futschek and Leila Teymournia, used a number of ultrasound examinations that allowed for a precise localization of the patients' organs from the outside. In a next step, the scientists analyzed the positioning of 60 patients, and evaluated the deviation of radiation in various spatial directions, such as to the right or left, and upward or downward (using 420 radiation plans for thirty patients). While it takes more time, an ultrasound system makes the shifts in position visible and traceable. If the deviation exceeds 0.8 cm, the radiology technicians are responsible for returning the patient to the correct position to ensure that the radiation only targets the specified area. In the subsequent study phase, Poljanc and her group calculated normal tissue compensation rates and the probability of tumor control. "This provides us with an overview of the probability that the tumor is targeted directly and the probability of side effects for individual patients," notes Poljanc. These approaches serve as forecasts and provide clues for the likelihood of healing. After a study period of some 2.5 years, with generous sponsorship of the Anniversary Fund of the Austrian National Bank, the scientists were able to implement the calculated average positioning inaccuracies in a radiation planning system. Sums up Leila Teymournia: "Depending on the calculation model used, the normal tissue compensation rate can vary widely in the results. While the use of Model A may yield a negligible complication rate, the same process calculated with Model B shows a deviation of up to 40 percent." Due to the absence of biological parameters, major discrepancies may result with different models. Nevertheless, the results of calculations can provide physicians with data for improving patient positioning accuracy and therefore, and improvement of treatment success.

    As part of their study of different radiation sources, Karin Poljanc, Tanja Futschek, and Leila Teymournia found that localization aids, such as ultrasound systems, are indispensable for accurate proton therapy of prostate carcinomas. In most cases, this combination leads to therapy results with a high level of tissue preservation.
    The future establishment of the cancer research and therapy center "Med-AUSTRON" in Wiener Neustadt will implement such a treatment method in Austria.

    Photo download: https://www.tuwien.ac.at/index.php?id=8087

    For further questions please contact
    Ass. Prof. Dipl.-Ing. Dr. Karin Poljanc
    Project Assistant Dipl.-Ing. Leila Teymournia
    Atomic Institute of Austrian Universities
    Vienna University of Technology
    Stadionallee 2 // 141, 1020 Vienna
    Phone: +43 1 58801-14191
    Fax: +43 1 58801 - 14199
    E-mail: kpoljanc@ati.ac.at
    E-mail: teymournia@ati.ac.at

    Released by:
    Daniela Hallegger
    TU Vienna - PR and Communication
    Operngasse 11/E011, A-1040 Vienna
    Phone +43 -1 -58801-41027
    Fax +43-1-58801-41093
    E-mail daniela.hallegger@tuwien.ac.at
    http://www.tuwien.ac.at/pr


    Weitere Informationen:

    http://www.tuwien.ac.at/aktuelles/news_detail/article/5210/


    Bilder

    4-field-box with photons
    4-field-box with photons

    None

    4-field-box with protons
    4-field-box with protons

    None


    Merkmale dieser Pressemitteilung:
    Physik / Astronomie
    überregional
    Forschungsergebnisse, Forschungsprojekte
    Englisch


     

    4-field-box with photons


    Zum Download

    x

    4-field-box with protons


    Zum Download

    x

    Hilfe

    Die Suche / Erweiterte Suche im idw-Archiv
    Verknüpfungen

    Sie können Suchbegriffe mit und, oder und / oder nicht verknüpfen, z. B. Philo nicht logie.

    Klammern

    Verknüpfungen können Sie mit Klammern voneinander trennen, z. B. (Philo nicht logie) oder (Psycho und logie).

    Wortgruppen

    Zusammenhängende Worte werden als Wortgruppe gesucht, wenn Sie sie in Anführungsstriche setzen, z. B. „Bundesrepublik Deutschland“.

    Auswahlkriterien

    Die Erweiterte Suche können Sie auch nutzen, ohne Suchbegriffe einzugeben. Sie orientiert sich dann an den Kriterien, die Sie ausgewählt haben (z. B. nach dem Land oder dem Sachgebiet).

    Haben Sie in einer Kategorie kein Kriterium ausgewählt, wird die gesamte Kategorie durchsucht (z.B. alle Sachgebiete oder alle Länder).